Tag Archives: H13-629_V2.5-ENU questions and answers

24 May

Newly Updated H13-629_V2.5-ENU Exam Questions To Be Your Preparation Materials

To all, the current version of HCIE-Storage is V2.5, when planning to be a HCIE-Storage certified, candidates are required to pass H13-629_V2.5 exam successfully. We have newly updated H13-629_V2.5-ENU exam questions, which is in English version, to be your best preparation materials for passing HCIE-Storage(Written) V2.5 certification exam. 

The most updated Huawei H13-629_V2.5-ENU exam questions of HCDAtest are correct with precise answers, which ensure that you can pass HCIE-Storage(Written) V2.5 exam in the first attempt. Huawei H13-629_V2.5-ENU free online test are online to help you test the demo first before getting the most updated H13-629_V2.5-ENU exam questions. If have any questions, please contact us via mail: [email protected].

Begin to Test:

1. Engineer C maps the storage to the file server for saving various files of the enterprise. One day, the file system was attacked by a virus, causing the file to fail to open normally. In order to allow the files to be accessed normally, the storage engineer performed a snapshot rollback operation.
Which of the following descriptions is false?

Question 1 of 25

2. A company has purchased a new batch of mainframes and storage devices, and will deploy the company's important business according to the plan. The storage network is required to have low latency, high performance, large bandwidth, lossless transmission, and can support Ethernet transmission. Which protocol should be selected?

Question 2 of 25

3. Which of the following statements about the evolution of storage network architecture is correct?

Question 3 of 25

4. An operation and maintenance engineer found a storage device alarm in the process of daily inspection and needed to perform rapid maintenance. Which of the following is wrong?

Question 4 of 25

5. In the following description of CPU grouping technology, which one is wrong?

Question 5 of 25

6. Huawei OceanStor Pacific series storage systems use link aggregation-based technology to achieve transmission link redundancy. When the cluster uses the IB network, which of the following about the number of the IB Ethernet ports needs to be configured on the back-end of the node storage network?

Question 6 of 25

7. Which statement about distributed storage is wrong?

Question 7 of 25

8. The HyperMetro feature implements I/O load balancing across arrays, that is, the I/O fragmentation method is sent on and off the write array. Which of the following statements about I/O fragmentation is correct?

Question 8 of 25

9. About the NDMP backup application planning, which of the following is wrong?

Question 9 of 25

10. When engineer A implements storage delivery, LUN cannot be scanned on the Linux service host side. Which of the following descriptions is wrong?

Question 10 of 25

11. The customer's production environment has high server performance, tight production network resources, and limited budget costs. The daily backup data volume is 1~2T, and the backup time is 3 hours. Which backup networking method is the most suitable?

Question 11 of 25

12. When planning an active-active disaster recovery solution, the business side needs to use cluster applications. Which of the following cluster applications can support the AA working mode?

Question 12 of 25

13. Which of the following statements about the SmartCache feature principle of Huawei OceanStor hybrid flash storage is correct?

Question 13 of 25

14. Huawei hyperconvergence has the function of adaptive global deduplication and compression, which can provide significant space reduction and reduce user TCD under reasonable resource consumption.
The correct order of the implementation process of adaptive global deduplication compression is:
1. Write class data block
2. Point to the data in the fingerprint table after deduplication
3. Upgrade from chance table to fingerprint table
4. Data block fingerprint entry opportunity table

Question 14 of 25

15. Which of the following descriptions about the InfoStamper features of the OceanStor 9000 storage system is incorrect?

Question 15 of 25

16. The storage engineer performs performance tuning on the existing storage system. According to the performance monitoring data front-end service port, the host application access delay is high. Which part of the performance tuning belongs to?

Question 16 of 25

17. In which of the following scenarios will OceanStor 9000 not trigger data balance?

Question 17 of 25

18. Regarding the protocol used by the mirror channel between controllers of Huawei Oceanstor hybrid flash storage, which of the following statement is correct?

Question 18 of 25

19. A bank purchased a new all-flash storage device (such as Huawei OceanStor all-flash memory), and the engineer initialized and configured the device. Which of the following operations is correct?

Question 19 of 25

20. During the read operation of the Thin LUN by the host, what technology is used to read data from the corresponding actual storage space in the storage pool?

Question 20 of 25

21. Regarding the description of Huawei OceanStor all-flash storage system, which one is wrong?

Question 21 of 25

22. A hospital needs to archive many patient cases and inspection results generated every day, but the storage resources are limited.
Under the premise of not occupying the transmission bandwidth, which deduplication method is the best?

Question 22 of 25

23. After employee A of a company logs in to the storage device of the company system, he finds that he has certain control authority. But can not modify the system time, and can not carry out user management.
Excuse me, which of the following roles does employee A have permissions?

Question 23 of 25

24. A customer deploys one set of storage in two cities, and uses asynchronous remote replication networking between the two storage arrays. Which of the following statements is correct? (Multiple Choice)

Question 24 of 25

25. During the construction of a data center, a media company purchased storage equipment from multiple manufacturers. CTOs want to centrally manage these storage devices through storage virtualization. Which of the following is not a function of storage virtualization?

Question 25 of 25


 


Recent Posts


Tags

H12-211-ENU H12-211-ENU online test H12-211-ENU practice test H12-221 H12-221-ENU H12-221-ENU online test H12-222 H12-222-ENU H12-223 H12-223-ENU H12-261 H12-261-ENU H12-261-ENU online test H12-261-ENU practice test H12-261-ENU questions and answers H12-311-ENU H13-511-ENU H13-511-ENU exam dumps H13-511-ENU latest dumps H13-511-ENU questions and answers H13-511-ENU real exam questions H13-511-ENU real questions H13-511-ENU test prep H13-511-ENU training materials H13-611-ENU H13-623-ENU exam dumps H13-629-enu H19-301-ENU exam dumps H19-307-enu H19-308 H19-308-ENU H19-308-ENU exam dumps H31-211-ENU H31-211-ENU exam dumps HCDA (Carrier IP) HCNA HCNA-Cloud-BCCP HCNA-HNTD HCNA Storage HCNP HCNP-R&S-IENP HCNP-Storage Huawei Certified Internetwork Expert-Routing & Switching Huawei Certified Network Associate-Building Cloud Computing Platform Video Conference