Huawei H19-105_V2.0-ENU Free Online Test – Prepare for Your HCSA-Sales-Data Center Facility V2.0 Certification Exam Well

Focus on HCDAtest’s real H19-105_V2.0-ENU exam questions, we have completed the comprehensive questions and answers to help you prepare for your Huawei HCSA-Sales-Data Center Facility V2.0 certification exam well.

Real Huawei H19-105_V2.0-ENU exam questions are the latest, covering the actual HCSA-Sales-Data Center Facility V2.0 exam topics and outlines to ensure you can prepare well. We also have the Huawei H19-105_V2.0-ENU free test online, which could be the demo to help you check the quality of the real Huawei H19-105_V2.0-ENU exam questions.

1. The cooling capacity adjustment range supported by NetCol5000-A042H full-cabinet row-level air-cooled variable frequency precision air conditioner is (), which can provide continuous cooling under low load in the afternoon, avoiding temperature and humidity fluctuations and unit reliability issues caused by frequent start and stop.

Question 1 of 33

2. Which of the following statements about surveillance cameras is wrong?

Question 2 of 33

3. UPS5000-E has the function of adjustable battery number, which avoids the replacement of the entire battery group due to a single battery failure and solves the problem of difficult maintenance of traditional UPS batteries. How many adjustable batteries does UPS5000-E (50kVA module) support?

Question 3 of 33

4. UPS2000-G-(6K-20K) has the strongest lightning protection design in the industry, with lightning protection level (), surge protection level (), which can avoid 90% failure caused by lightning strikes and reliably protect the AC input port of the back-end equipment.

Question 4 of 33

5. The total current of the battery pack is 1000A, and 3 sets of batteries are configured. The most economical configuration of the cable from the main switch box to the branch switch box is: ()

Question 5 of 33

6. The NetEco management system adopts a large-capacity design architecture, which can support the access of massive devices and the access of up to () 10,000 measurement points using a single X86 server. At the same time, the system operates smoothly and the CPU utilization rate is no higher than ()

Question 6 of 33

7. The battery type supported by UPS2000-G is ().

Question 7 of 33

8. What kind of inlet and outlet wiring methods can the FusionModule2000 integrated power distribution cabinet implement?

Question 8 of 33

9. PDU8000 precision power distribution cabinet protection level ().

Question 9 of 33

10. In UPS5000-A system, which of the following battery configuration is unreasonable?

Question 10 of 33

11. The capacity management module of the NetEco management system can manage the resource capacity information in the computer room.
Which of the following capacity factors falls within the management scope of NetEco?

Question 11 of 33

12. In FusionModule2000, when the columns occupy the closed channel space in the column-surrounding scene, how should the skylight be adapted?

Question 12 of 33

13. Which of the following models can be equipped with an external large-capacity battery charger for fast recharging?

Question 13 of 33

14. The UPS5000-E power module adopts a fan fault-tolerant design. When two of the fans fail, how much load can the power module still carry?

Question 14 of 33

15. What is the total IT load power of the FusionModule1000A V2R3 version 40-foot IT solution?

Question 15 of 33

16. How many 42KW air conditioners can the FusionModule2000 integrated power distribution cabinet support at most?

Question 16 of 33

17. A system is configured with a 1H battery backup time, and the discharge termination voltage of a single battery cell should be selected ().

Question 17 of 33

18. UPS2000-G- (6K-20K) has an output power factor of (), adapting to new IT loads and significantly improving the system's load capacity.

Question 18 of 33

19. What is the maximum power of the IT cabinet of FusionModule500 & FusionModule800?

Question 19 of 33

20. What is the maximum IT load and power modules supported by the FusionModule2000 integrated UPS?

Question 20 of 33

21. The asset management module of the NetEco management system can manage the equipment in the computer room: Which of the following equipment is not within the management scope of the NetEco asset management module?

Question 21 of 33

22. NetEco management system can be deployed on () virtual machine software, saving the purchase of servers through virtualization deployment.

Question 22 of 33

23. The NetEco6000 management system can use Huawei eSpace VCN500 products to implement video storage: One VCN500 product can connect to () cameras.

Question 23 of 33

24. UPS5000-E (25-125kVA) power module height (), system efficiency ().

Question 24 of 33

25. The Data Center Design Specification GB50174-2017 stipulates that when selecting a site, a data center using cooling should have sufficient water supply and ().

Question 25 of 33

26. What is the range of battery cabinets in FusionModule800?

Question 26 of 33

27. The temperature control products used in the FusionModule1000A V2R3 version T solution are ().

Question 27 of 33

28. Which circuit breaker is used in the main circuit of PDU8000 precision power distribution cabinet?

Question 28 of 33

29. When the voltage of a single cell in a battery pack reaches (), it means that the battery pack is in a risky state.

Question 29 of 33

30. When the NetEco management system is connected to a third-party device outside the micromodule, what monitoring hardware is usually used for access?

Question 30 of 33

31. Which circuit breaker is used in the PDU8000 precision power distribution cabinet?

Question 31 of 33

32. The capacity management module of the NetEco management system can be connected to a third-party () system to receive equipment change information, automatically generate a change application form, and track the processing process.

Question 32 of 33

33. How many power modules does the FusionModule2000 integrated UPS 50K model support at most?

Question 33 of 33


 


Recent Posts


Tags

H12-211-ENU H12-211-ENU online test H12-211-ENU practice test H12-221 H12-221-ENU H12-221-ENU online test H12-222 H12-222-ENU H12-223 H12-223-ENU H12-261 H12-261-ENU H12-261-ENU online test H12-261-ENU practice test H12-261-ENU questions and answers H12-311-ENU H13-511-ENU H13-511-ENU exam dumps H13-511-ENU latest dumps H13-511-ENU questions and answers H13-511-ENU real exam questions H13-511-ENU real questions H13-511-ENU test prep H13-511-ENU training materials H13-611-ENU H13-623-ENU exam dumps H13-629-enu H19-301-ENU exam dumps H19-307-enu H19-308 H19-308-ENU H19-308-ENU exam dumps H31-211-ENU H31-211-ENU exam dumps HCDA (Carrier IP) HCNA HCNA-Cloud-BCCP HCNA-HNTD HCNA Storage HCNP HCNP-R&S-IENP HCNP-Storage Huawei Certified Internetwork Expert-Routing & Switching Huawei Certified Network Associate-Building Cloud Computing Platform Video Conference